Cable Gland Size Chart

How to Use a Cable Gland Size Chart

Using a cable gland size chart can help you choose the right size of cable gland for your application. The chart contains information about the thread type, diameter range, and overall dimensions for various cable glands. To use the chart, first identify the thread type required for your application. Next, find the corresponding column on the chart and locate the diameter range that matches your cable or wire. Finally, cross-reference this information with the overall dimensions to select a gland that will fit properly.

It is important to note that using an improperly sized cable gland can result in performance issues or even safety hazards. For example, if a cable gland is too small for its intended use, it may not be able to adequately seal against moisture or dust ingress. On the other hand, if a gland is too large it may damage cables or create an unsafe environment by allowing contaminants into sensitive equipment areas.

By using a cable gland size chart properly and selecting an appropriately sized gland for your application needs, you can ensure optimal performance and safety while minimizing risk factors that could potentially undermine productivity and safety standards.

Factors Affecting Size Selection

When selecting a cable gland size, there are several factors that need to be considered. The first factor is the cable diameter. It is important to choose a size that can accommodate the diameter of the cable without causing any strain or damage. Cable glands come in various sizes, ranging from small to large, so it is essential to measure the cable’s diameter accurately.

Another factor that affects cable gland size selection is the material used for manufacturing. Different materials have different properties and require different sizes of cable glands. For instance, if you are working with a flammable gas or liquid, you will need to use an intrinsically safe cable gland made of brass or stainless steel instead of plastic.

Lastly, environmental conditions also play a crucial role in selecting the right size for your application. If you are working in harsh environments like offshore rigs or chemical plants where corrosion and extreme temperatures may be present, it is best to select a robust and durable material type such as nickel-plated brass or nylon 6/6 for your gland fitting choice.

Measuring for Correct Size

When it comes to cable glands, getting the correct size is crucial for securing cables and ensuring that they remain protected from harm. In order to measure for the correct size of gland, you will first need to determine the diameter of your cable. This can be done using a caliper or measuring tape.

Once you have determined the diameter of your cable, consult a cable gland size chart to determine which size gland will fit best. It’s important to note that different manufacturers may have slightly different sizing standards, so it’s always best to double-check with the manufacturer’s specification sheets before making a purchase.

It’s also worth noting that some cable glands may require additional measurements such as thread pitch or overall length in order to ensure proper fitment. Taking these extra steps during the measuring process will help ensure that you get the right size gland for your application and avoid costly mistakes down the line.

Conclusion

In conclusion, understanding the cable gland size chart is crucial when it comes to selecting the right cable glands for your specific application. The chart provides vital information such as thread sizes, dimensions, and maximum cable diameters that can be accommodated by each gland size. It is important to note that choosing a gland that is too small or too big can lead to various problems such as poor sealing or damage to cables.

When selecting a cable gland size, it is essential to consider factors such as environmental conditions, the type of cables being used, and their diameter. For instance, if you are working in a harsh environment with high levels of moisture or dust, you may need to select a gland with better sealing capabilities. Similarly, if you are using multiple cables with varying diameters, you may need to select different sizes of glands depending on the largest cable diameter.

In summary, proper selection and installation of cable glands ensure that your cables are protected from external elements while maintaining optimal performance levels. Therefore it’s always important to refer back to the chart before making any decisions on which size of the gland will suit your specific needs best.

Cagland Cable Gland Size Chart
Cagland Cable Gland Size Chart

Cagland Manufacturer can support you with the below cable gland size chart. Any questions, please feel free to contact us.

M Cable Gland

Thread Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Wholesale Package (pcs/bag)
M10*1.0 2-5 10.1-10.5 8.9 8 14 100
M12*1.5 3-6.5 12.1-12.5 10.3 8 16 100
M14*1.5 4-8 14.1-14.5 12.3 8 19 100
M16*1.5 4-8 16.1-16.5 14.3 8 19 100
M18*1.5 5-10 18.1-18.5 16.3 8 22 100
M20*1.5 6-12 20.1-20.5 18.3 9 24 100
M22*1.5 10-14 22.1-22.5 20.3 10 27 100
M24*1.5 12-15 24.1-24.5 22.3 10 27 100
M27*1.5 14-18 27.1-27.5 25.3 10 32 100
M30*1.5 16-21 30.1-30.5 27.8 11 36 50
M32*1.5 16-21 32.1-32.5 30.3 11 36 50
M36*1.5 18-25 36.1-36.5 33.8 12 42 50
M40*1.5 24-32 40.1-40.5 38.3 14 52 20
M50*1.5 32-38 50.1-50.5 48.3 14 62 20
M55*1.5 37-48 55.1-55.5 52.8 20 67 20
M63*1.5 37-48 63.1-63.5 61.3 20 67 20
M75*2 42-50 75.1-75.5 69.8 25 81 10
M80*2 60-70 80.1-80.5 77.8 25 97 5
M100*2 75-85 100.1-100.5 97.8 25 110 1

PG Cable Gland

Thread Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Package (pcs/bag)
PG7 3-6.5 12.6-13 11.2 8 16 100
PG9 4-8 15.3-15.7 13.8 8 19 100
PG11 5-10 18.7-19.1 17.2 8 22 100
PG13.5 6-13 20.5-20.9 19 9 24 100
PG16 8-14 22.6-23 21.1 10 27 100
PG19 12-15 24.1-24.5 22.3 10 27 100
PG21 13-18 28.4-28.8 26.7 10 33 100
PG25 14-20 30.1-30.5 27.8 12 36 50
PG29 18-25 37.1-37.5 35.4 12 42 50
PG36 24-32 47.1-47.5 45.4 14 52 20
PG42 30-41 54.1-54.5 52.4 14 62 20
PG48 35-45 59.4-59.8 57.7 14 64 20
PG63 42-50 71-71.5 69.3 29 77 10

NPT Cable Gland

Model Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Package (pcs/bag)
C-NPT3/8 4-8 14.5 15 20 100
C-NPT1/2 6-12 17.9 13 24 100
C-NPT3/4 14-18 23.2 15 29 100
C-NPT1 18-25 29.2 16 36 50
NPT3/8 4-8 17.3-17.8 14.5 15 20 100
NPT1/2 6-12 21.5-22 17.9 13 24 100
NPT3/4 14-18 26.8-27.3 23.2 15 29 100
NPT1 18-25 33.5-34 29.2 16 36 50

G Cable Gland

Model Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Package (pcs/bag)
G3/8 4-8 16.7-17.1 14.9 15 20 100
G1/2 6-12 21-24.4 18.6 13 24 100
G3/4 14-18 26.5-26.9 24.1 15 29 100
G1 18-25 33.3-33.7 30.2 16 36 50

S-M Cable Gland

Thread Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Wholesale Package (pcs/bag)
M12*1.5 3-6.5 12.1-12.5 10.3 8 15 100
M16*1.5 4-8 16.1-16.5 14.3 8 18 100
M18*1.5 5-10 18.1-18.5 16.3 8 1 100
M20*1.5 6-12 20.1-20.5 18.3 9 23 100
M22*1.5 10-14 22.1-22.5 20.3 10 25 100
M25*1.5 12-15 25.1-25.5 23.3 10 27 100
M32*1.5 16-21 32.1-32.5 30.3 11 35 50
M36*1.5 18-25 36.1-36.5 33.8 12 40 50
M40*1.5 24-32 40.1-40.5 38.3 14 47 20
M50*1.5 32-38 50.1-50.5 48.3 14 58 20

D-M Cable Gland

Thread Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Wholesale Package (pcs/bag)
M12*1.5 4-8 12.1-12.5 10.3 8 15 100
M16*1.5 6-10 16.1-16.5 14.3 8 18 100
M20*1.5 10-14 20.1-20.5 18.3 9 23 100
M25*1.5 14-18 25.1-25.5 23.3 10 27 100
M32*1.5 18-25 32.1-32.5 30.3 11 35 50
M40*1.5 24-32 40.1-40.5 38.3 14 47 20
M50*1.5 42-50 50.1-50.5 48.3 14 58 20

S-PG Cable Gland

Thread Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Package (pcs/bag)
S-PG7 3-6.5 12.6-13 11.2 8 15 100
S-PG9 4-8 15.3-15.7 13.8 8 18 100
S-PG11 5-10 18.7-19.1 17.2 8 21 100
S-PG13.5 6-12 20.5-20.9 19 9 23 100
S-PG16 10-14 22.6-23 21.1 10 25 100
S-PG19 12-15 24.1-24.5 22.3 10 27 100
S-PG21 14-18 28.4-28.8 26.7 10 30 100
S-PG25 16-21 30.1-30.5 27.8 12 34 50
S-PG29 18-25 37.1-37.5 35.4 12 40 50
S-PG36 24-32 47.1-47.5 45.4 14 47 20
S-PG42 32-38 54.1-54.5 52.4 14 60 20
S-PG48 37-44 59.4-59.8 57.7 14 63 20

Spiral Flex Cable Gland

RPG

Thread Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Package (pcs/bag)
R-PG7 3-6.5 12.6-13 11.2 8 16 100
R-PG9 4-8 15.3-15.7 13.8 8 19 100
R-PG11 5-10 18.7-19.1 17.2 8 22 100
R-PG13.5 6-12 20.5-20.9 19 9 24 50
R-PG16 10-14 22.6-23 21.1 10 27 50
R-PG21 14-18 28.4-28.8 26.7 10 33 50
RL-PG7 3-6.5 12.6-13 11.2 15 16 100
RL-PG9 4-8 15.3-15.7 13.8 15 19 100
RL-PG11 5-10 18.7-19.1 17.2 15 22 100
RL-PG13.5 6-12 20.5-20.9 19 15 24 50
RL-PG16 10-14 22.6-23 21.1 15 27 50
RL-PG21 14-18 28.4-28.8 26.7 15 33 50

Brass Cable Gland

CPG

Thread Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Package (pcs/bag)
C-PG7 3-6.5 12.6-13 11.2 6 14 100
C-PG9 4-8 15.3-15.7 13.8 6 17 100
C-PG11 5-10 18.7-19.1 17.2 6 20 100
C-PG13.5 6-12 20.5-20.9 19 7 22 100
C-PG16 10-14 22.6-23 21.1 7 24 100
C-PG21 14-18 28.4-28.8 26.7 7 30 100
C-PG29 18025 37.1-37.5 35.4 8 40 50
C-PG36 24-32 47.1-47.5 45.4 8 50 20
C-PG42 32-38 54.1-54.5 52.4 9 60 20
C-PG48 37-44 59.4-59.8 57.7 10 65 20
C-PG63 42-50 71-71.5 69.3 10 78 10

Stainless Steel Cable Gland

CM

Thread Cable Range (mm) Installing hole(mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Wholesale Package (pcs/bag)
C-M8*1.0 2-5 8.1-8.5 6.9 6 12 100
C-M10*1.0 2-5 10.1-10.5 8.9 6 14 100
C-M12*1.5 3-6.5 12.1-12.5 10.3 6 14 100
C-M16*1.5 4-8 16.1-16.5 14.3 6 18 100
C-M18*1.5 5-10 18.1-18.5 16.3 6 20 100
C-M20*1.5 6-12 20.1-20.5 18.3 7 22 100
C-M22*1.5 10-14 22.1-22.5 20.3 7 24 100
C-M24*1.5 12-15 24.1-24.5 22.3 7 28 400
C-M25*1.5 14-18 25.1-25.5 23.3 7 30 400
C-M27*1.5 14-18 27.1-27.5 25.3 8 30 315
C-M30*1.5 16-21 30.1-30.5 27.8 8 34 150
C-M32*1.5 16-21 32.1-32.5 30.3 8 36 150
C-M36*1.5 18-25 36.1-36.5 33.8 8 40 120
C-M40*1.5 24-32 40.1-40.5 38.3 9 50 80
C-M50*1.5 32-38 50.1-50.5 48.3 9 60 48
C-M63*1.5 37-44 63.1-63.5 61.3 10 75 27
C-M75*2 42-50 75.1-75.5 69.8 10 78 150
C-M80*2 55-60 80.1-80.5 77.8 15 88 10
C-M88*2 65-70 88.1-88.5 85.8 15 98 10
C-M100*2 75-85 100.1-100.5 97.8 17 110 5

Multi hole Metric Thread

Multi hole Metric Thread

Hole Number Thread Cable Management (mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Wholesale Package (pcs/bag)
Multi Holes M12*1.5 1.2-3 12 8.5 18/19 50
Multi Holes M16*1.5 1.6-4 16 15 22/22 50
Multi Holes M20*1.5 2.5-6 20 15 27/27 50
Multi Holes M25*1.5 4-8 25 15 33/33 50
Multi Holes M32*1.5 5-10 32 15 41/41 20
Multi Holes M40*1.5 11-13 40 20 50/50 10
Multi Holes M50*1.5 12-15 50 20 62/62 10

Multi hole PG Thread

Multi hole PG Thread

Hole Number Thread Cable Management (mm) Thread O.D. (mm) Thread Length (mm) Spanner Size (mm) Wholesale Package (pcs/bag)
Multi Holes PG7 1.2-3 12.5 8.5 18/19 50
Multi Holes PG9 1.2-3 15.2 8.5 22/19 50
Multi Holes PG11 1.6-4 18.6 10 24/22 50
Multi Holes PG13.5 2-5 20.4 10 27/24 50
Multi Holes PG16 2.5-6 22.5 11 30/27 50
Multi Holes PG21 4-8 28.3 12 36/33 50
Multi Holes PG29 5-10 37 12 46/41 20
Multi Holes PG36 11-13 47 15 57/50 10
Multi Holes PG42 12-15 54 15 64/62 10

Inquiry form